21
In more detail...
Specications/
Troubleshooting
BLY1 Wireless Alarm System
Type AC/AC Adaptor with 3-pin UK style
Housing material ABS
Rated Supply 230VAC 50HZ supply
Output Extra Low Voltage (AC15V max at 500mA AC)
Troubleshooting
1) Control unit (CU)
2)Wireless Door/Window contact detector (MC)
3)Wireless PIR detector (PIR)
4)Wireless remote control (optional accessory)
Control Panel Power Supply Adaptor
Symptoms Possible causes and cures
Power indicator and all status LEDs are off
without any response
No power supply to unit.
Check connectors to mains and alkaline
battery.
Power indicator does not light up but the sta-
tus LEDs or TAMPER LEDs are on.
Main supply is out. It is operating from alkaline
battery. Check power connections/adaptor.
TAMPER (Red) ashing.
Low backup battery condition;
replace 9V PP3 Alkaline battery as soon as
possible.
No response to wireless detector
transmissions.
Are detectors programmed correctly?
Are PIR Detectors in warm up time (During
the rst 2 minutes from the batteries
installing)?
Are detectors within radio range of the control
unit? Control unit not armed.
Symptoms Possible causes and cures
Does not detect opening of door or window
(Red LED does not ash)
Check that batteries are correctly installed.
Check that magnet is correctly positioned.
Built-in buzzer makes a sound Batteries are low. Replace batteries
Symptoms Possible causes and cures
Does not transmit
(Red LED does not ash).
Check that the battery is correctly installed.
Battery low, replace battery.
Symptoms Possible causes and cures
Does not detect movement
(Red LED does not ash).
Is PIR’s LED turned off?
Is the PIR in its “sleep” condition (See Page 15).
PIR causes false “intruder” alarms.
Check that PIR is not pointed at heat sources
or moving objects, and is not mounted above
a radiator or other heater.
PIR will not trigger alarm when the system
is set.
PIR in “sleep” condition.
Built-in buzzer makes a sound. Batteries are low. Replace batteries.
REMARK: if you have any
problem with the wireless alarm
system, press the RESET switch
inside the control unit. The system
will reset to factory default settings,
but the detectors will need to be
re-programmed again.
Reset Switch
Wireless Alarm System.indd 22 01/06/2012 10:57