Installing your System
BLY1 Wireless Alarm System
11
Getting started...
Powering up the Wireless PIR Detector(s):
1. Remove battery cover and insert two LR03 “AAA” size alkaline batteries incorrect polarity
as shown.
2. Replace battery compartment cover.
When the PIR is rst powered up it will take 2 minutes for it to warm-up before it can be linked
to the control unit.
Linking the detectors to the Control unit.
1. Press and hold the “Learn” button for over 5 seconds in standby mode to enter learn
mode. The control unit will beep twice to conrm and the learn LED will turn on.
2. Trigger the device within 10 seconds ensuring it is kept at least 0.5m away from the control
unit. To trigger:
2.1 a magnetic contact, activate the MC detector by moving the magnet away
(greater than 40mm) from the arrow near the red LED.
When a MC Detector has been learnt successfully, Z1, Z2, Z3 or Z4 zone LED
(depending on which next zone is unprogrammed) will be constantly lit.
Learn MC
Greater than 40mm
NOTE: After the rst 2 minutes, the PIR will enter a test mode period for the next 15
minutes. During the test mode period, the PIR will constantly detect for movement so
that it gives enough time to link it to the control unit. When this period has expired,
after the PIR detects any further movement, it will go to sleep and not detect any
movement for 2 minutes. This is just an energy saving feature.
AAA 1.5V
AAA 1.5V
LR03 size 1.5V
LR03 size 1.5V
Wireless Alarm System.indd 12 01/06/2012 10:57